Ergo TPS

Line: Prime

Compactness, performance, robustness and transportability are the main features of the ERGO TPS breathable air compressors. Equipped with four different pumping units (MCH 13, MCH 16, MCH 21 and MCH 23), all in TPS (Tropical Plus Superdry) version and powered by three-phase electric motors. The compressors are equipped with a complete panel with a monitoring system including pressure gauges, autostop with adjustable pressure switch, automatic condensate discharge and rotation direction control. The models of this line have two connections for high pressure tubes (from 232 to 330 bar) and an increased filtering system with two Hyperfilters.

Ergo TPS

Line: Prime

Technical drawing

H : 770 mm - W : 1120 mm - D : 630 mm
H : 30.31 in - W : 44.09 in - D : 24.80 in
Disegno tecnico compressori
Ergo TPS
Ergo TPS

Table for product type

To understand which product, proceed as appropriate.

Pumping group capacity

MCH 13
Three-phase Electric Motor - 235 l/m - 14,10 m³/h - 8.30 CFM FAD
MCH 16
Three-phase Electric Motor - 315 l/m - 18,90 m³/h - 11.12 CFM FAD
MCH 21
Three-phase Electric Motor - 345 l/m - 20,70 m³/h - 12.18 CFM FAD
MCH 23
Three-phase Electric Motor - 380 l/m - 22,80 m³/h - 13.42 CFM FAD

Filling time: *

* Cylinder filling time from 10 l-0/200 bar (cylinder filling measurement from 0 to 200 bar ± 5%)
MCH 13
Three-phase Electric Motor - 8 min. 30 sec.
MCH 16
Three-phase Electric Motor - 6 min. 20 sec.
MCH 21
Three-phase Electric Motor - 5 min. 40 sec.
MCH 23
Three-phase Electric Motor - 5 min. 10 sec.

Operating pressure

232 - 300 - 330 bar
3365 - 4351 - 4786 PSIG

Net weight

MCH 13 - Three-phase Electric Motor - 174 kg - 384 Lbs
MCH 16 - Three-phase Electric Motor - 184 kg - 406 Lbs
MCH 21 - Three-phase Electric Motor - 184 kg - 406 Lbs
MCH 23 - Three-phase Electric Motor - 184 kg - 406 Lbs

Noise level

MCH 13
Three-phase Electric Motor - 80,7 db
MCH 16
Three-phase Electric Motor - 82,3 db
MCH 21
Three-phase Electric Motor - 83 db
MCH 23
Three-phase Electric Motor - 83 db
Gruppo Pompante Compressori Coltri
  • MCH 13 TPS
  • Number of stages: 3
  • MCH 16 TPS
  • Number of stages: 3
Gruppo Pompante Compressori Coltri
  • MCH 21 TPS
  • Number of stages: 3
  • MCH 23 TPS
  • Number of stages: 3
Parti macchina Compressori Coltri
Parti macchina Compressori Coltri
Parti macchina Compressori Coltri
Parti macchina Compressori Coltri
Components
  • 1.
    Frame
  • 2.
    Control pannel
  • 3.
    Power button
  • 4.
    Stop button
  • 5.
    Condensate drain button
  • 6.
    Oil level light
  • 7.
    Light incorrect rotation direction
  • 8.
    Operating hours counter
  • 9.
    Inner cab/cooled air temperature
  • 10.
    Emergency button
  • 11.
    Automatic switch off pressure switch
  • 12.
    Third stage pressure gauge
  • 13.
    Second stage pressure gauge
  • 14.
    First stage pressure gauge
  • 15.
    Refill tube coupling
  • 16.
    Condensate drain valves
  • 17.
    Oil level indicator
  • 18.
    Oil drain valve
  • 19.
    Purifier filter
  • 20.
    Transport handle
  • 21.
    Condensate collection tank
  • 22.
    Motor
  • 23.
    Compressor
  • 24.
    Air filter
  • 25.
    Condensate separator
  • 26.
    First stage
  • 27.
    Second stage
  • 28.
    Third Stage
  • 29.
    Monobloc
  • 30.
    Oil fill cap
  • 31.
    Safety valve
  • 32.
    Maintaining valve
  • 33.
    Cooling fan
  • 34.
    Track
  • 35.
    Vibration damping
  • 36.
    Oil pump
  • 37.
    Oil filter
  • 38.
    HP condensate separator
CircuitoPpressione Compressori Coltri
Components
  • 1.
    Suction filter
  • 2.
    Intake valve 1st stage
  • 3.
    Discharge valve 1st stage
  • 4.
    Cooling pipe 1st-2nd stage
  • 5.
    Intake valve 2nd stage
  • 6.
    Discharge valve 2nd stage
  • 7.
    Safety valve - 1st stage
  • 8.
    Pressure gauge 1st stage
  • 9.
    Cooling pipe 2nd / condensate separator LP
  • 10.
    LP condensate separator
  • 11.
    Safety valve - 2nd stage
  • 12.
    Pressure gauge 2nd stage
  • 13.
    Intake valve 3rd stage
  • 14.
    Discharge valve 3rd stage
  • 15.
    Final cooling pipe
  • 16.
    HP condensate separator
  • 17.
    Safety valve
  • 18.
    Pressure gauge
  • 19.
    HP condensate separator High Efficiency
  • 20.
    Purifier filter
  • 21.
    Pressure maintaining valve
  • 22.
    Pressure switch
  • 23.
    Flex hoses