BOOSTER LINE.

Ace VI Zero Loss

Top performance, minimal noise

Quiet, powerful, and high-performance: the ACE VI ZERO LOSS is the high-pressure booster that combines efficiency and operating comfort, even in the most noise-sensitive environments.

Designed for compressing technical gases with suction pressures from 2 to 5 bar, ACE VI ZERO LOSS is equipped with a 3-stage pumping unit, plus a dedicated gas recovery stage, to minimize waste and optimize each work cycle.

With a flow rate ranging from 250 to 690 l/min and 11 or 15 kW three-phase electric motors, it guarantees high performance and continuity even under heavy loads.
The purification system Hyperfilter with dual activated carbon cartridges ensures the purity of the outgoing gas, while the control panel handles condensate drainage, shutdown, interstage pressure gauges and electronic pressure switch fully automatically.

All of this is enclosed in a soundproof frame designed to keep noise emissions to a minimum, providing a quieter, safer and more efficient working environment.

Watch it closely

Simplicity comes as standard

Imagine having a compressor capable of great performance and endowed with extraordinary robustness. What would all this be without absolute simplicity in operating it? We believe that’s what innovation is for: to make it simpler.

And now for all the details
4-stage pumping unit with gas recovery
  • Aluminum monoblock
  • Forced lubrication with low-pressure gear pump
  • First stage for gas recovery
  • Pipes, fittings and nuts made of AISI 316 stainless steel
  • Intermediate condensate separators after the second and third stages
  • High-pressure final condensate separator
  • Safety valves after each compression stage
  • Special cast iron cylinders with low roughness lapping
  • Forged aluminum connecting rods
  • Forged steel crankshaft
  • First-, second- and third-stage high-flow fill valves
  • Heavy-duty roller bearings
  • Hardened steel fourth stage with 6 special cast iron piston rings
  • Second and third stages with thrust pads to eliminate lateral forces on the pistons
  • Filter system Hyperfilter activated carbon
Electric motor

One of the key parts of the compressor: the motor transfers motion to the pumping unit through the belt. The three-phase electric motor is available on this model from 11 to 1 5 kW.

Purification system Hyperfilter for nitrogen

Placed after the last compressor separator and before the pressure maintenance valve, the purification system Hyperfilter enables reliable treatment of the breathing air, according to DIN EN 12021¹ when using original filter cartridges. The separator present between the 2nd and 3rd stages of the purification circuit makes it possible to extract as much moisture as possible. The filtering capacity with inlet air at 20°C and 200 bar is 52,500 m³.

Electrical cabinet
  • ON/OFF switch with motor protection switch.
  • Electromechanical pressure switch that stops the compressor at the final pressure.
  • Drainage of all separators between individual stages and also of the final separator during compressor operation
  • Timer for automatic condensate drainage device.
  • Integrated no-load startup (automatic discharge each time the unit is turned off).
  • Condensate collection tank 5 liters, with silencer; capacity about 3 liters, for environmentally friendly disposal of condensate.
  • Interstage pressure gauges display the operating pressure for individual compression stages. This pressure information allows the tightness of the valves (inlet and outlet) of each stage to be checked and potential sources of failure to be quickly identified.
Frame

Silenced cabin chassis with vertical development, made for environments requiring low noise level. Oil level and drain reported externally, control console equipped with inter-stage gauges, oil pressure gauge, internal temperature indicator, presence and wrong phase sequence alarm, oil shortage alarm, and run stop and manual condensate drain controls allow easy operation and maintenance of the compressor. Made of steel with scratch-resistant powder coating in color Black RAL 9005.

The best for you,
the best for your work

The compressors Booster prove it: the best possible machine is the one that meets the specific needs of “that” customer, customizing the answer in terms of reliability and performance. Whether we are talking about air, helium, hydrogen, nitrogen, the customer comes before the solution-this is our “credo.”

Standard Equipment

Double filter system Hyperfilter PED certified
Condensate separation system
Frame color Black RAL 9005

Technical specifications.

Type of gas

Air – Nitrogen

Suction pressure

Min. 2 bar Max. 5 bar

Pressure rating

250 bar / 330 bar

Operating pressure

232 bar / 300 bar

Max working pressure

420 bar

Allowable temperature range

-10° C ÷ +40° C

Allowable altitude range

0 ÷ 1.500 m SLM

Maximum allowed inclination

15°

Design

Cabinet insonorizzato con fonoassorbente

Operating voltage, standard

400 V, 50 Hz

Other operating voltages
On three-phase electric motors at 60 hz power (kW / hp) increase by 20%.

230 V, 50 Hz / 440 V, 60 Hz / 230 V, 60 Hz

Oil

Olio sintetico Coltri ST 755

Oil change interval

1 year / 1,000 h

Frame

Steel – Color Black RAL 9005 – Powder coated – Scratch resistant

Compressor

Pump group flow rate
11 KW

From 250 l/min a 620 l/min
From 15 m3/h a 37 m3/h
From 8.8 CFM a 21.9 CFM

15 KW

From 280 l/min a 690 l/min
From 17 m3/h a 41.4 m3/h
From 9.9 CFM a 24.4 CFM

Purification system

2 Hyperfilter a carbone attivo

Cooling air flow
11 KW

1.960 m3/h

15 KW

1.960 m3/h

Weight
Standard model. Dimensions and weight may vary depending on accessories..
11 KW

373 kg
943 lb

15 KW

463 kg
1.020 lb

Dimensions
(W x D x H)

93,5 x 130,2 x 175,3 cm
36.8 x 51.3 x 68.3 in

Noisiness

Engine

Power
11 KW

11 kW
15 Hp

15 KW

15 kW
20 Hp

Engine type
11 KW

Three-phase electric

15 KW

Three-phase electric

Operating voltage/frequency
Different voltage and frequency available upon request.
11 KW

400 V, 50 Hz

15 KW

400 V, 50 Hz

Rated current
11 KW

23 A

15 KW

31 A

Engine RPM (RPM)
11 KW

2.910

15 KW

2.920

Protection class

IP55